What This Example Demonstrates

A single end-to-end runner that executes every implemented 2D and 3D benchmark in cfd-validation and emits a unified validation report with convergence status and per-benchmark metrics. Mathematical invariants are verified at the end of the run.

BenchmarkDimensionNotes
LidDrivenCavity2DRe = 100 canonical separator
BifurcationFlow2DSymmetric + asymmetric Murray-law split
VenturiFlow2DBernoulli pressure-drop check
SerpentineFlow2DDean secondary flow
BifurcationFlow3D3DCasson blood in Y-junction
VenturiFlow3D3DCavitation number check
SerpentineFlow3D3DDean number vs threshold

Key Code Snippet

use cfd_core::error::Result;
use cfd_core::physics::fluid::blood::CassonBlood;
use cfd_validation::benchmarks::{
    Benchmark, BenchmarkConfig, BenchmarkRunner,
    BifurcationFlow, BifurcationFlow3D, LidDrivenCavity,
    SerpentineFlow, SerpentineFlow3D, VenturiFlow, VenturiFlow3D,
};

// Heterogeneous benchmark set collected behind Box<dyn Benchmark<f64>>
// at the non-hot suite-entry boundary (per standards dyn-policy exception).
let benchmarks: Vec<Box<dyn Benchmark<f64>>> = vec![
    Box::new(LidDrivenCavity::new(1.0, 1.0, 100.0)),
    Box::new(BifurcationFlow::symmetric()),
    Box::new(BifurcationFlow3D::new(CassonBlood::normal_blood())),
    // ... VenturiFlow, SerpentineFlow, VenturiFlow3D, SerpentineFlow3D ...
];

let config = BenchmarkConfig { tolerance: 1e-4, ..Default::default() };
let results: Vec<_> = benchmarks.iter()
    .map(|b| b.run(&config))
    .collect::<Result<Vec<_>>>()?;
let report = BenchmarkRunner::generate_report(&results);

for r in &report.benchmarks {
    let converged = r.convergence.last().is_some_and(|&c| c < config.tolerance);
    println!("- {:<30} [{}]", r.name, if converged { "CONVERGED" } else { "NON-CONVERGED" });
}

Physics Background

The suite spans canonical fluid-dynamics regimes — lubrication (lid-driven cavity), branching-network haemodynamics (Murray- and Hagen-Poiseuille-driven bifurcation split), inviscid-recoverable pressure drop (Bernoulli over Venturi geometries), and curved-channel secondary flow (Dean vortices). Each benchmark’s convergence is judged against a tolerance on its last-iteration residual. The closing invariant check at line 88 (All mathematical invariants verified) asserts that the suite’s physics laws — mass conservation, Murray’s-law flow split, and Bernoulli pressure-drop relations — hold across the combined runs.

Book Chapter