Diffusion MRI Acquisition and Q-ball ODFs

Diffusion-weighted MRI measures how water self-diffusion varies with gradient direction and strength. RITK separates three concerns:

ConcernOwnerChapter
Validated gradient metadata (b-values, directions, frames, codecs, reorientation)ritk-diffusion-schemeDiffusion Gradient Schemes
Orientation models derived from voxel signalsritk-diffusionThis chapter (Q-ball ODFs; DTI, DKI, CSD, and NODDI follow the same pipeline pattern)
Streamline integration over a local orientation fieldritk-tractographyDeterministic Streamline Tractography

This chapter focuses on the physics that relates gradient pulses to signal attenuation — the bridge between the validated metadata in the scheme chapter and the model-fitting algorithms documented in the Diffusion Models chapter.

From gradient pulse to b-value

For the idealized Stejskal–Tanner pulsed-gradient experiment, the diffusion weighting is

b = γ² G² δ² (Δ − δ/3)

where γ is the gyromagnetic ratio, G the gradient amplitude, δ the pulse duration, and Δ the pulse separation. The measured signal for a Gaussian diffusion tensor D is

S(b, g) = S₀ exp(−b gᵀ D g)

Thus (b) has dimensions of time per area, conventionally s/mm²; it is not a diffusivity. DiffusionWeighting stores the canonical SI value (s/m²) internally through the Aequitas quantity system and exposes the scanner-facing s/mm² value at the API boundary. See the scheme chapter for the type-level contract and Stejskal and Tanner, “Spin Diffusion Measurements”.

Relationship to the gradient scheme

The Diffusion Gradient Schemes chapter establishes four guarantees that every model fitting depends on: validated directions, unambiguous coordinate frames, scheme-level reorientation, and shell grouping. The Diffusion Models chapter documents how all five implemented models (DTI, DKI, ODF, CSD, NODDI) consume these guarantees — this chapter focuses on the physics shared by all of them.

From scheme to signal to model

The pipeline established by the three chapters in this part is:

  1. Validated scheme — the Diffusion Gradient Schemes chapter ensures every direction carries a declared frame, a physically typed weighting, and a validated unit-vector contract.
  2. Orientation model — the Diffusion Models chapter documents the transformation from validated scheme + voxel signals → fitted field. Five models are implemented: DTI (log-linear tensor), DKI (nonlinear kurtosis), ODF (analytical Q-ball), CSD (non-negative fODF), and NODDI (3-compartment biophysical).
  3. Streamline geometry — the Deterministic Streamline Tractography chapter integrates the fitted orientation field into Gaia polyline curves.
use ritk_diffusion_scheme::{GradientFrame, GradientScheme};
use ritk_spatial::Vector;

let scheme = GradientScheme::from_seconds_per_square_millimeter(
    vec![
        (0.0, Vector::new([0.0, 0.0, 0.0])),
        (1_000.0, Vector::new([1.0, 0.0, 0.0])),
        (1_000.0, Vector::new([0.0, 1.0, 0.0])),
    ],
    GradientFrame::ImageAxis,
)?;
assert_eq!(scheme.len(), 3);
Ok::<(), ritk_diffusion_scheme::GradientSchemeError>(())

Format coordinate contracts

  • FSL bvec directions are image-axis coordinates. The three rows are x, y, and z components; the companion bval sequence supplies s/mm² values. DiffusionMaps retains this ImageAxis frame. When a fitted field is placed in DtiVolume, the volume validates that frame and converts the external [column, row, depth] direction order to RITK’s image-index [depth, row, column] order exactly once. LPS maps are rejected at this boundary because physical-to-index conversion requires image geometry that DtiVolume does not own.
  • Standard DICOM Diffusion Gradient Orientation (0018,9089) is in the patient coordinate system and RITK labels it LPS. Diffusion b-value (0018,9087) is s/mm². The current reader accepts top-level attributes from classic one-instance-per-volume inputs; it does not guess private vendor fields or enhanced functional groups. See DICOM PS3.3 C.8.13.5.9.
  • NA-MIC DWI NRRD stores one nominal DWMRI_b-value. A gradient’s squared norm relative to the largest gradient norm scales that volume’s effective b-value. The measurement frame maps the gradient into world coordinates, after which RAS is converted once to RITK’s LPS physical frame. See the NA-MIC DWI NRRD convention.

These distinctions prevent a numerically valid direction from being applied in the wrong physical frame.

Analytical Q-ball estimation

Q-ball imaging estimates an orientation distribution function (ODF) without assuming a single diffusion tensor. RITK first normalizes weighted signals by the mean b0 signal and fits an even-degree real spherical-harmonic expansion:

E(g) = Σₗ,ₘ cₗₘ Yₗₘ(g)

The weighted samples must occupy one q-space shell. OdfConfig makes the allowed absolute b-value tolerance explicit; an off-shell acquisition returns MixedShells instead of entering a physically invalid angular fit. The fitted OdField retains the scheme frame, so evaluation directions and reported peaks keep an unambiguous coordinate meaning.

The least-squares system is augmented with a Laplace–Beltrami penalty. For coefficient degree l, the diagonal penalty factor is l(l + 1), so the configured nonnegative weight suppresses high-degree oscillation. The Funk–Radon transform then acts degree by degree:

ψₗₘ = 2π Pₗ(0) cₗₘ

This is the analytical Q-ball construction of Descoteaux et al., “Regularized, Fast, and Robust Analytical Q-Ball Imaging”. It produces an ODF, not a constrained-spherical-deconvolution fiber orientation density; those quantities must not be interpreted interchangeably.

OdfConfig validates harmonic degree, regularization, the b0 threshold, and the single-shell tolerance. Estimation fails on non-finite signals, non-finite values created by baseline normalization or the numerical solve, missing b0 or weighted samples, nonpositive baseline, an underdetermined basis, or a failed solve. Evaluation also rejects overflow created by finite coefficients and finite basis values. OdField stores coefficients contiguously and reuses its basis metadata for repeated evaluation. evaluate_on_grid returns one flat row-major allocation rather than a pointer-chasing grid of rows.

The signal-to-streamlines example uses a known tensor to verify that the recovered antipodal ODF peak matches its analytical x axis.

The signal-to-streamlines example closes the loop: known tensor → synthetic signals → model fit → direction field → streamlines.